From: Nanozyme-based aptasensors for the detection of tumor biomarkers
Cancer type | Biomarker | Aptamer | Nanozyme | Substrate | Detection Method | Electrode | Linear Range | LOD | Sensitivity | Recovery (RSD) | Assay Time | Ref. |
---|---|---|---|---|---|---|---|---|---|---|---|---|
− | HER2 | HER2 | Mn3O4 Pd@Pt | HQ/H2O2 | DPV | GE | 0.1 − 100 ng/mL | 0.08 ng/mL | − | − | − | [73] |
Ovarian Cancer | CA125 | Aptamer 2.26 Aptamer 2.43 | Au | DAB//H2O2 | ALFA | − | 7.5 − 200 U/mL | 5.21 U/mL | − | 86.5 − 114.8% | − | [75] |
CA125 | CeO2 | TMB/H2O2 | Colorimetry | − | 1.0 − 10.0 U/mL | 0.43 mU/mL | − | 95.4–104.0% (< 6.7%) | − | [76] | ||
HCC | GP73 | GP73 | RGO-CMCS-Hemin/Pt@Pd | TMB/H2O2 | Colorimetry | − | 10.0–110.0 ng/mL | 4.7 ng/mL | − | 98.2–107.0% (1.90–5.44%) | 120 min | [78] |
GP73 | H-rGO-Mn3O4 | TMB/H2O2 | SWV | SPE | 0.01–100.0 ng/mL | 0.0071 ng/mL | 2.441 µA/µM/cm2 | 98.66–121.11% | − | [79] | ||
GPC3 | GPC3 | H-R-Pt@Pd | TMB/H2O2 | Colorimetry | − | 10–300 ng/mL | 5.06 ng/mL | − | 105.94–116.33% (0.93– 3.08%) | − | [80] | |
GPC3 | H-rGO-Pd | AgNO3/ H2O2 | DPV | SPE | 0.01–10.0 µg/mL 10.0–100.0 µg/mL | 3.30 ng/mL | 1.535 µAµM− 1 cm− 2 | 103.78–106.52% (1.89–8.81%) | 30 min | [81] | ||
− | VEGF165 | VEGF165 | (MnCo)Fe2O4 | 4-CN/H2O2 | PEC | FTO | 1 × 10− 2−1 × 104 pg/mL | 0.1 fg/mL | − | 100.9–101.7% (2.12–2.15%) | 60 min | [83] |